SPECIFICATION
1. INPUT VOLTAGE RANGE……………………………………………12/24 VOLTS DC ±20%
2. INPUT CURRENT……………………………………………………..70/35AMP
3. OUTPUT VOLTAGE RANGE…………………………………………220 VOLT AC RMS ±10%
4. MAX. CONTINUOUS POWER………………………………………. 800 WATT
5. OUTPUT FREQUENCY ………………………………………………50 Hz ±1Hz
6. SURGE CAPABILITY (PEAK POWER)……………………………..1500WATT/0.3 SECOND
7. OPTIMUM EFFICIENCY…………………………………………….. >90%
8. NO LOAD CURRENT DRAW………………………………………...<200mA
9. WAVE FORM…………………………………………………………..MODIFIED SINE WAVE
10. AUTOMATIC ELECTRONIC CIRCUIT FEATURES:
10.1. HIGH INPUT VOLTAGE SHUTDOWN…………………….. 15~16/30-32 VOLT DC
10.2. LOW INPUT VOLTAGE AUDIBLE ALARM………….……. 10.5~11/21-22 VOLT DC
10.3. LOW INPUT VOLTAGE SHUTDOWN……………………... 15~16/30-32VOLT DC
10.4. OVER TEMPERATURE SHUTDOWN………………………170°F
THE UNIT WILL BE AUTOMATICALLY RESTARTED AFTER APPROXIMATELY
15 MINUTES OF COOL DOWN.
10.5. OVERLOAD SHUTDOWN………………………………….850~900 WATTS
11. SYSTEM DISPLAY
11.1. SYSTEM NORMAL OPERATION……………………….…..GREEN LED INDICATOR
11.2. OVER TEMPERATURE………………………………………RED LED INDICATOR
11.3. OVER LOAD………………………………………………….RED LED INDICATOR
11.4. LOW HIGH BATTERY……………………………………….RED LED INDICATOR
12. ENVIRONMENT OPERATIONAL CONDITIONS:
12.1. ELEVATION………………………………………0 TO 10,000 FEET ABOVE SEA LEVEL
12.2. OPERATING…………………………………………………..-10°F TO 110°F
12.3. STORAGE……………………………………………………..5°F TO 140°F
13. PHYSICAL:
13.1. NET WEIGHT…………………………………………………1.8KG
13.2. DIMENSIONS……………………………188 mm W X 128 mm D X 50 mm H