热度 10
2012-4-21 13:04
1737 次阅读|
0 个评论
HOT RUNNER SYSTEM Temperature controller Instruction Manual (NH110818A) CATALOG Introduction ………………………………………………………………………2 Panel function description ……………………………………………………3 Basic instructions ………………………………………………………………4 Start up and shut down…………………………………………………………………………………4 How to change the default temperature ( automatic mode ) or output percentage ( manual mode ) ………………………………………………………………………………………………… 4 how to change the mode of…………………………………………………………………………… 4 How to view the output voltage and output current percentage………………………………… 4 How to change sensor input types and degrees Fahrenheit Conversion ( special function 1 )…4 How to change the PID parameters and self-tuning model selection ( special function 2 ) ……5 PID self-tuning learning…………………………………………………………………………………5 How to restore the factory settings…………………………………………………………………… 6 The main parameters and points for attention in use …………………6 Common faults and solutions …………………………………………………7 Points for attention in use ………………………………………………………8 Introduction The dual-core microprocessor system, the main control using special industrial embedded FLASH microprocessor, the other with a special 24 delta sigma high precision A / D conversion circuit ( 24Bit accuracy; can be precisely detected thermocouple at 0.0001 degrees C changes between 18 times per second, the conversion rate; data processing capability is extremely strong, fast running speed, temperature speed, temperature without overshoot, precise temperature control, stable and reliable work. the thermostat by us for the mold temperature control and design, advanced without overshoot PIDD algorithm and PID self-tuning technology, ensure the thermostat not overshoot, do not owe, but drawing temperature, high temperature control precision, fast temperature rising, strong anti-interference ability, complete functions, simple operation. The thermocouple input terminal of the amplifier circuit using a unique protection technology, input is resistant to 220VAC high voltage input without damage, can prevent the wrong lines caused by machine scrapped, reduce installation risk. The load overload and short circuit protection, the machine starts automatically detects the load, if when the load power is greater than the rated value or the load short circuit of the output end or mistakenly heating output terminal receives the temperature line, the machine automatically shut down output, and an alarm, need to remove the fault after a reboot to start. The SCR short circuit protection, when the internal SCR accidental short circuit or is damaged, the machine stops automatically output, prevent because SCR short circuit caused by mold temperature too high and out of control, the protection of customer mold damage, can reduce the loss to the minimum. The advanced power management and protection system, 85-264Vac 47-63Hz wide input range, high input voltage protection ( when the input voltage is increased to 270VAC, or the voltage wrong connection of 380V, the controller immediately to protect and stop the output, until the voltage returns to normal), machine with multiple state regulatory requirement, each machine the EFT test ( European standard ), can adapt to the industrial environment in a variety of interference, especially for long continuous work; It can be set as high as 0-537 ℃ or 32-999℉temperature output. The industrial use of amplifier circuit, has strong anti-interference capability, stable temperature drift, signal amplification, small zero drift, high accuracy, especially in strong interference environment of industrial work. The low voltage, low power automatic start, automatic dehumidifying, prevents mold with water condensation and damage to the mold and controller; The working parameters of power failure memory function, can record the user to set the main parameters. The automatic and manual operation, when the thermocouple open or damaged can be manually selected heating power. J、K type thermocouple input select, ℃and℉ show selection, simple operation, intuitive. It has open thermocouple and reverse detection. The complete working state display, error message, can quickly provide machine information, in order to better for the operator to provide reliable basis for.