    测量系统的温度变化将带来热膨胀,从而改变 电容 ,在电流中引入额外噪声。如果在环境温度(不加热也不冷却)下进行测量,在测量期间系统温度一般是足够稳定的。不过,如果需要与温度有关的测量,那么温度稳定性应当优于0.1K。 Temperature changes in the measurement system cause thermal expansions and, therefore, changing capacitances, introducing additional noise in the current. If measurements are performed atambient temperature without additional heating or cooling, thesystem temperature is usually sufficiently stable during measure-ment. However, if temperature-dependent measurements are nec-essary, the temperature stability should be better than 0.1K.   考虑到光吸收问题,在测量光电导率时,必须使样本和测量系统加热最小化。这要求使用具有良好 热导率 的材料。对于这种应用,最好的选择是使用蓝宝石基底和铜电极来安装样本,如图2所示。除了具有出众的体积电阻率以及良好的抗吸水性表面,蓝宝石还具有优良的热导率,而且在大部分光谱范围内都不会吸收光波。为了使系统吸收的热量最小化,要小心谨慎,只对样本进行照明(例如,要聚焦光线或使用激光束),不要包围电极和 屏蔽层 。系统加热可能带来电流的增加,这与光电导率测量非常相似。 To measure photoconductivity, it’s essential to minimizeheating of the sample and measurement system due to lightabsorption. This requires using materials with good heat conduc-tivity. For this application, the best choice is to use a sapphiresubstrate and copper electrodes to mount the sample, as shown in Figure 2 . In addition to its excellent volume resistivity and asurface with good resistance to water absorption, sapphire hasgood thermal conductivity and doesn’t absorb light over a widespectral range. To minimize the amount of heat the systemabsorbs, exercise care to illuminate only the sample (e.g., byfocusing the light or using a laser beam), not the surroundingelectrodes and shields. System heating can cause a rise in cur-rent, much as it does in photoconductivity measurements.       了解更多信息      要想了解有关 6517A 型静电计 / 高阻表 或者吉时利其他系列数字源表的更多信息,请点击http://www.keithley.com.cn/products/localizedproducts/highresistance/6517a,或者联系吉时利公司:全国免费电话800-810-1334手机用户请拨打440-650-1334。 登录吉时利官方微博(http://weibo.com/keithley)与专家进行互动。  8008101334 4006501334 010-84475556 电容http://www.keithley.com.cn/news/prod110121 半导体器件实验室http://www.keithley.com.cn/re/sdl 屏蔽层http://www.keithley.com.cn/llm/a/17.html 6517A型静电计/高阻表http://www.keithley.com.cn/products/localizedproducts/highresistance/6517a
  • 热度 14
    2011-12-1 11:31
    1125 次阅读|
    0 个评论
    测量系统的温度变化将带来热膨胀,从而改变 电容 ,在电流中引入额外噪声。如果在环境温度(不加热也不冷却)下进行测量,在测量期间系统温度一般是足够稳定的。不过,如果需要与温度有关的测量,那么温度稳定性应当优于0.1K。 Temperature changes in the measurement system cause thermal expansions and, therefore, changing capacitances, introducing additional noise in the current. If measurements are performed atambient temperature without additional heating or cooling, thesystem temperature is usually sufficiently stable during measure-ment. However, if temperature-dependent measurements are nec-essary, the temperature stability should be better than 0.1K.   考虑到光吸收问题,在测量光电导率时,必须使样本和测量系统加热最小化。这要求使用具有良好 热导率 的材料。对于这种应用,最好的选择是使用蓝宝石基底和铜电极来安装样本,如图2所示。除了具有出众的体积电阻率以及良好的抗吸水性表面,蓝宝石还具有优良的热导率,而且在大部分光谱范围内都不会吸收光波。为了使系统吸收的热量最小化,要小心谨慎,只对样本进行照明(例如,要聚焦光线或使用激光束),不要包围电极和 屏蔽层 。系统加热可能带来电流的增加,这与光电导率测量非常相似。 To measure photoconductivity, it’s essential to minimizeheating of the sample and measurement system due to lightabsorption. This requires using materials with good heat conduc-tivity. For this application, the best choice is to use a sapphiresubstrate and copper electrodes to mount the sample, as shown in Figure 2 . In addition to its excellent volume resistivity and asurface with good resistance to water absorption, sapphire hasgood thermal conductivity and doesn’t absorb light over a widespectral range. To minimize the amount of heat the systemabsorbs, exercise care to illuminate only the sample (e.g., byfocusing the light or using a laser beam), not the surroundingelectrodes and shields. System heating can cause a rise in cur-rent, much as it does in photoconductivity measurements.       了解更多信息      要想了解有关 6517A 型静电计 / 高阻表 或者吉时利其他系列数字源表的更多信息,请点击http://www.keithley.com.cn/products/localizedproducts/highresistance/6517a,或者联系吉时利公司:全国免费电话800-810-1334手机用户请拨打440-650-1334。 登录吉时利官方微博(http://weibo.com/keithley)与专家进行互动。   吉时利仪器公司(中国)市场部 (T) 8008101334,  8610 82255010,  82255011 电容http://www.keithley.com.cn/news/prod110121 半导体器件实验室http://www.keithley.com.cn/re/sdl 屏蔽层http://www.keithley.com.cn/llm/a/17.html 6517A型静电计/高阻表http://www.keithley.com.cn/products/localizedproducts/highresistance/6517a
  • 热度 18
    2011-6-13 11:01
    9581 次阅读|
    29 个评论
    曾经见过一个产品,信号输出,采用变压器隔离的,为了提高屏蔽效果,采用了双端接地,但因为设备输出是浮地的,机壳也是塑料材质,设备端接地采用下图所示的接法,在做辐射发射试验时超标。 设备端得接地是通过变压器的中心抽头串一个电容C1实现的,本意很好,但却恶化了对外辐射发射性能。 对于内部电路,高频信号会通过变压器耦合电容C2之间耦合到信号线和屏蔽层上,因为信号线是双绞线,所以两条信号线的共模干扰互相抵消了。但因为有接地阻抗,在接地阻抗上就会有一个Vn电压,屏蔽电缆就成为了单极天线,对外形成辐射,如下图所示。 解决方法是使用普通电缆,这样就去掉了发射天线,在辐射发射试验中顺利通过了测试。 接地的知识的就写这么多吧! 本接地系列文章列表: 接地--基本概念 接地-目的 接地-布局 接地--浪涌试验时为什么只烧毁功放板 接地-数字地和模拟地如何接? 接地-磁珠不要乱用 接地-接地带来的辐射 接地-信号线一定要使用屏蔽层吗?
  • 热度 16
    2011-4-21 16:57
    4813 次阅读|
    4 个评论
    本文最初由本人发表于成都《电子报》1999年11月14日第49期第13版     本人采用电话机专用集成电路 MC34018P 制作了一套对讲门铃,铃声柔和悦耳,音量适中,并可双方同时呼叫,且交直流两用,平时不消耗电能。     本机工作原理见图 1 ,电路原理见图 2。       KB-1 是呼叫开关, KA-1 、 KA-2 是通话开关,可使用电话机叉簧开关。 1DZ1 、 3DZ1 可选用稳压值相同的任何型号二极管, 1DZ1 稳压值 6V , 3DZ1 稳压值 7V 。话筒采用驻极体话筒。 VR1 、 VR2 一般调在中间位置,若话筒输入信号过强,可适当调整 VR2 ,如果接收声音有含混感觉,适当调整 VR1 即可。 VOL 为音量开关,使用时根据自己的习惯、喜爱自行调节。本机除喇叭外的所有元件均装在一块 9cm × 9cm 的印板上。        使用时先按下呼叫开关 KB-1 向对方发送呼叫信号,然后松开 KB-1 ,再按下 KA 即可进行通话对讲。同样,对方听到呼叫后,也要按下 KA 方可对讲。通话结束后松开 KA 整机电源自动关闭。           甲、乙两机间用一根双芯屏蔽线连接,屏蔽层作地线。如果再装一个手柄 ( 可直接使用电话机成品手柄 ) ,通过一个四刀双掷开关转换(转换喇叭、话筒和通话开关的接线顺序 ) ,本机还可免提、手柄两用。不过因手柄内喇队与本机输出阻抗不合,需要在输出端增加一个线间变压器,可用电话机铃声输出变压器或者收音机输出变压器,初、次级颠倒使用即可。试验证明,本机相距 1000 米使用仍有 良好的效果。 相关资料下载: 自制有线对讲门铃.rar (原文地址:http://qijie72.blog.163.com/blog/static/281836292007103082054463/)  