摘要:添加一个电荷泵提供±5V电源轨运算放大器的内部高边电流检测放大器。这一修改使该放大器感应电流下降到0V的共模输入。可以修改,以适应双向电流检测应用电路。Maxim > App Notes > Amplifier and Comparator Circuits Power-Supply Circuits
Keywords: current-sense amplifier, charge pump, op amp, bidirectional current sensing Sep 20, 2007
APPLICATION NOTE 4078
Extend Current-Sense Amplifier's Input Range Down to 0V
Abstract:Adding a charge pump provides ±5V supply rails to the operational amplifier internal to a high-side current-sense
amplifier. This modification enables that amplifier to sense currents down to 0V common-mode inputs. The circuit can be modified
to accommodate bidirectional current-sense applications.
A similar article appeared in the February 15, 2007 issue of Electronic Design magazine.
In addition to the traditional lead-acid battery, modern electric/hybrid cars often include a large capacit……