Figure 2 shows a plot of daily VOS drift measurements of 30 individual ISL28133 amplifiers over a continuous 572 day period at +25°C. Application Note 1729
Author: Bob Pospisil
ISL28133 Long Term Drift
Figure 2 shows a plot of daily VOS drift measurements of 30 100k
individual ISL28133 amplifiers over a continuous 572 day
period at +25°C. The 30 units were connected in a gain of 10k 10 +2.5V
(see Figure 3), mounted on a single PC board and kept at room ……