Selecting the Optimum Test Tones and Test Equipment for Successful High-Speed ADC Sinewave Testing
推荐星级:
时间:2019-12-24
大小:71.75KB
阅读数:404
上传用户:二不过三
查看他发布的资源
下载次数
0
所需E币
4
ebi
新用户注册即送 300 E币
更多E币赚取方法,请查看
close
资料介绍
Abstract: An earlier application note, "Coherent Sampling vs. Window Sampling," covered the basics of coherent sampling. It showed differences between tests performed with coherent sampling and windowed sampling conditions. The following technical discussion is a follow-up note, which deals with the proper selection of test tones and instruments to successfully test and evaluate a high-speed ADC's AC performance. Maxim > App Notes > A/D and D/A Conversion/Sampling Circuits Basestations/Wireless Infrastructure High-Speed Signal Processing Keywords: high-speed ADCs, analog to digital converters, coherent sampling, input test tone, sinewave testing, Dec 18, 2002 clock frequency, sampling frequency, equipment, low phase noise, signal generator, logic analyzer, synthesizer, data acquisition software, MATLAB APPLICATION NOTE 1819 Selecting the Optimum Test Tones and Test Equipment for Successful High-Speed ADC Sinewave Testing Abstract: An earlier application note, "Coherent Sampling vs. Window Sampling," covered the basics of coherent sampling. It showed differences between tests performed with coherent sampling and windowed sampling conditions. The following technical discussion is a follow……