Precision Current-Transmitter/Source-Sink Calibrator Has Wide Compliance Range
时间:2019-12-24
大小:43.32KB
阅读数:279
查看他发布的资源
资料介绍
Abstract: Based on a precision op amp (MAX4236), this loop-powered, high-compliance, precision current sink (or source) can be modified for use as a 4–20mA sink transmitter. Maxim > App Notes > Amplifier and Comparator Circuits
Keywords: current-loop transmitter, loop calibrator, sink/source calibrator, precision op amps Jan 31, 2011
APPLICATION NOTE 4573
Precision Current-Transmitter/Source-Sink Calibrator Has Wide
Compliance Range
Abstract:Based on a precision op amp (MAX4236), this loop-powered, high-compliance, precision current sink (or source) can