Zynq UltraScale+ RFSoC Data Sheet:DC and AC
Summary
The Xilinx® Zynq® UltraScale+™ RFSoCs are available in -2 and -1 speed grades, with -2E devices having the highest performance. The -2LE and -1LI devices can operate at a VCCINT voltage at 0.85V or 0.72V and are screened for lower maximum static power. When operated at VCCINT = 0.85V, using -2LE and -1LI devices, the speed specification for the L devices is the same as the -2I or -1I speed grades. When operated at VCCINT = 0.72V, the -2LE and -1LI performance and static and dynamic power is reduced.DC and AC characteristics are specified in extended (E), industrial (I), and military (M) temperature ranges. Except the operating temperature range or unless otherwise noted, all the DC and AC electrical parameters are the same for a particular speed grade (that is, the timing characteristics of a -1 speed grade extended device are the same as for a -1 speed grade industrial device). However, only selected speed grades and/or devices are available in each temperature range.
The XQ references in this data sheet are specific to the devices available in XQ Ruggedized packages. See the Defense-Grade UltraScale Architecture Data Sheet: Overview (DS895) for further information on XQ Defensegrade part numbers, packages, and ordering information.
All supply voltage and junction temperature specifications are representative of worst-case conditions. The parameters included are common to popular designs and typical applications. This data sheet, part of an overall set of documentation on the Zynq UltraScale+ RFSoCs, is available on theXilinx website at www.xilinx.com/documentation.